C-DOT DSS MAX RSU INSTALLATION MANUAL

Strany 2

Chapter 2. 8 C-DOT DSS MAX-XL

Strany 3 - © 1999 BY C–DOT, NEW DELHI

RSU INSTALLATION MANUAL 9 Chapter 3. RSU Cable Preparation And Laying 3.1. INTRODUCTION Following are the main cables required for RSU installation

Strany 4 - Preface

Chapter 3. 3.2. CABLE PREPARATION ON RSU SIDE 3.2.1. Detail of RSU Clock Cable (BM-L/BM-XL) C-DOT ASSY NO. : ACB-RSUXRCXN-100 DRAWING NO. : Fi

Strany 5 - Table of Contents

RSU CABLE PREPARATION AND LAYING RSU INSTALLATION MANUAL 11

Strany 6

Chapter 3. 12 C-DOT DSS MAX-XL

Strany 7 - Introduction

RSU CABLE PREPARATION AND LAYING 3.2.2. Details of Digital Cables at RSU At RBM end, for connecting RSU to DDF/MDF, 4 Pair or 8 Pair digital Trunk

Strany 8 - 6 C-DOT DSS MAX-XL

Chapter 3. TAB NO. RETAINED : For Module -1 2 2 CABLE MARKER : RA `uu' RA `xx' RB `uu' RB `xx' DESTINATION PLACEMENT : *

Strany 9

RSU CABLE PREPARATION AND LAYING RSU INSTALLATION MANUAL 15

Strany 10 - 8 C-DOT DSS MAX-XL

Chapter 3. Connections for Digital Trunk Cable RBM end (4 Pair Cable) Module No. Pin No. `A' `B' `C' 1 Blue (uu) Orange

Strany 11 - Chapter 3

RSU CABLE PREPARATION AND LAYING Signal Names for Digital Trunk Cable (RBM End) Module No. Pin No. A B C 1 TX_P {1} TX_P {7} TX_N {1}

Strany 12

SystemPractices Section No. 401-305-0513 Issue 03, October 1999 C-DOT DSS MAX-XL RSU INSTALLATION MANUAL © 1999, C-DOT Printed in India

Strany 13 - RSU INSTALLATION MANUAL 11

Chapter 3. Cable No.'s for Different RBM No.'s RBM No. uu vv xx yy 02 01 02 03 04 04 05 06 07 08 06 09 10 11 12 08 13 14 15 16 10 17 18

Strany 14 - 12 C-DOT DSS MAX-XL

RSU CABLE PREPARATION AND LAYING Ground Cable - 32/0.2mm Black Colour PVC wire. ACIO cable -- Jumper wire with PVC sleeve CABLE UNIT COLOR CODE

Strany 15 - RSU INSTALLATION MANUAL 13

Chapter 3. Slot - 12 15 Connector - B B TAB NO. RETAINED : For Module 3 - 4 4 CABLE MARKER : - RRSA RRSB ASSEMBLY P

Strany 16 - 14 C-DOT DSS MAX-XL

RSU CABLE PREPARATION AND LAYING RSU INSTALLATION MANUAL 21

Strany 17 - RSU INSTALLATION MANUAL 15

Chapter 3. \DESIGN\DSSMAX\MAX-XL\RSU-XLIM\RSXLC3 22 C-DOT DSS MAX-XL

Strany 18

RSU CABLE PREPARATION AND LAYING 3.2.2.3. Digital Trunk Cable (Using 8 Pair Cable) C-DOT ASSY NO. : ACB-ERSURN03-000 DRAWING NO. : Fig. 3.3 CA

Strany 19

Chapter 3. DESTINATION PLACEMENT : Digital Part - Stripped wire to MDF. For ACIO Copy 0 Copy 1 Frame TSU TSU Slot 12 15 Connector B B TAB N

Strany 20

RSU CABLE PREPARATION AND LAYING RSU INSTALLATION MANUAL 25

Strany 21 - RSU INSTALLATION MANUAL 19

Chapter 3. A. Connections for Digital Trunk Cable RBM end (Using 8 pair cable) Module No. Pin No. A B C 1 Blue (uu) Orange (xx) White (

Strany 22 - 20 C-DOT DSS MAX-XL

RSU CABLE PREPARATION AND LAYING 3.2.3. Details of BP Terminal Cable for BM-XL C-DOT ASSY NO. : ACB-MAXXBPTX-000 DRAWING NO. : Fig. 3.4a, 3.4b

Strany 23 - RSU INSTALLATION MANUAL 21

C-DOT DSS MAX-XL RSU INSTALLATION MANUAL ISSUE 03 OCTOBER 1999 ASVINA 2056 SERIES 300 : INSTALLATION CSP SECTION NO. 401-305-0513 THIS C–DOT S

Strany 24 - 22 C-DOT DSS MAX-XL

Chapter 3. 3.2.4. Details of BP Terminal Cable for BM-L C-DOT ASSY NO. : ACB-RSUVTEZX-000 DRAWING NO. : Fig. 3.4d, 3.4b,3.4c CABLE PART NO. : M

Strany 25 - RSU INSTALLATION MANUAL 23

RSU CABLE PREPARATION AND LAYING RSU INSTALLATION MANUAL 29

Strany 26

Chapter 3. 30 C-DOT DSS MAX-XL

Strany 27 - RSU INSTALLATION MANUAL 25

RSU CABLE PREPARATION AND LAYING RSU INSTALLATION MANUAL 31

Strany 28

Chapter 3. \DESIGN\DSSMAX\MAX-XL\RSU-XLIM\RSXLIBTCNOTE: USE SILICON RUBBER SLEEV ONLENGTHS L1, L2 32 C-DOT DSS MAX-XL

Strany 29 - RSU INSTALLATION MANUAL 27

RSU CABLE PREPARATION AND LAYING 3.3. CABLE PREPARATION ON MBM SIDE FOR RSU For each RSU, eight lengths of 4 Pair shielded cables (4 for bus-0 and

Strany 30 - 28 C-DOT DSS MAX-XL

Chapter 3. DESTINATION PLACEMENT : MDF ASSEMBLY PROCEDURE : Wire Wrapping Refer fig. 3.5 (a), 3.5 (b) and table 3-6,3-7. Note * The exact length o

Strany 31 - RSU INSTALLATION MANUAL 29

RSU CABLE PREPARATION AND LAYING Signal Names for Digital Trunk Cable (CM End) Module No. Pin No. A B C 1 RX_P {1} -- RX_N {1} 2 RX_

Strany 32 - 30 C-DOT DSS MAX-XL

Chapter 3. 36 C-DOT DSS MAX-XL

Strany 33 - RSU INSTALLATION MANUAL 31

RSU CABLE PREPARATION AND LAYING RSU INSTALLATION MANUAL 37

Strany 34 - 32 C-DOT DSS MAX-XL

Preface The objective of this manual is to provide necessary information & guidance for the installation of an RSU. Since most of the chapters

Strany 35 - RSU INSTALLATION MANUAL 33

Chapter 3. 38 C-DOT DSS MAX-XL

Strany 36

RSU CABLE PREPARATION AND LAYING RSU INSTALLATION MANUAL 39

Strany 37

Chapter 3. 40 C-DOT DSS MAX-XL

Strany 38 - 36 C-DOT DSS MAX-XL

RSU INSTALLATION MANUAL 41 Chapter 4. Jumper Settings and Modem Set-Up 4.1. JUMPER SETTING ON ESM & ESL CARDS 4.1.1. APC-ESM 397/H-S01 (IN CM-

Strany 39 - RSU INSTALLATION MANUAL 37

Chapter 4. Jumper Settings for W9-W16 (BPU COPY 0) RBM NO. Shorting Position Function 2 W13,W15,W16,W9,W10,W11 Copy id = 82 4 W13,W16,W9,W10

Strany 40 - 38 C-DOT DSS MAX-XL

JUMPER SETTINGS AND MODEM SET-UP Note : 1. The mechanical jumpers to be shorted as shown above. 2. The jumpers not mentioned to be left open. 4.3

Strany 41 - RSU INSTALLATION MANUAL 39

Chapter 4. JUMPER SETTINGS FOR W9-W16 (BPU COPY 1) BM NO. HORTING POSITION FUNCTION 2 W11, W12, W13, W14, W15 Copy id = 83 4 W12, W13, W

Strany 42 - 40 C-DOT DSS MAX-XL

JUMPER SETTINGS AND MODEM SET-UP 4.4.1. Dial Up Mode Working Connect terminal to modem, power on modem/terminal, issue AT commands to achieve the f

Strany 43 - Chapter 4

Chapter 4. 4. Set serial baud rate and modem baud rate to 9600 bps 5. Disable DTR signal Note : 1. For configuring modem using AT commands; power o

Strany 44 - Table No. 4-2

JUMPER SETTINGS AND MODEM SET-UP AT&D0&W0↵ (Ignore DTR signal and save) Now set the jumper inside modem as follows : Set lease/dial to leas

Strany 45

Table of Contents Preface ...

Strany 46

Chapter 4. 48 C-DOT DSS MAX-XL

Strany 47 - RSU INSTALLATION MANUAL 45

49 C-DOT DSS MAX-XL Chapter 5. MDF - Installation 5.1. GENERAL The MDF installation, on the RBM side, is similar to the MDF installation for C-DOT-S

Strany 48 - 46 C-DOT DSS MAX-XL

Chapter 5. 5.3. DIGITAL TRUNK CABLE TERMINATION ON CM TO DDF (FOR RSU PCMS) While laying the cables on CM side, details given in table 5-1 may be see

Strany 49 - RSU INSTALLATION MANUAL 47

MDF - INSTALLATION FIG. 5.1 (a)4 PAIR DIGITAL TRUNK CABLE TERMINATION ON RBM END MDF (FOR RSU PCMs)L2L2L4L4TxTxRxRxRxRxL1L3L3TxL1TxWHORWHBLGNBNWHWHB

Strany 50 - 48 C-DOT DSS MAX-XL

Chapter 5. FIG. 5.1 (b)8 PAIR DIGITAL TRUNK CABLE TERMINATION ON RBM END MDF (FOR RSU PCMs)L2L2L4L4TxTxRxRxRxRxL1L3L3TxL1TxWHORWHBLGNBNWHWHSLWHBLRDRDR

Strany 51 - MDF - Installation

MDF - INSTALLATION FIG. 5.24 PAIR DIGITAL TRUNK CABLE TERMINATION ON CM END DDF (FOR RSU PCMs)\DESIGN\DSSMAX\MAX-XL\RSU-XLIM\RSXLIF2L2L2L4L4RxRxTxTx

Strany 52 - 50 C-DOT DSS MAX-XL

Chapter 5. 54 C-DOT DSS MAX-XL

Strany 53 - RSU INSTALLATION MANUAL 51

MDF - INSTALLATION CABLE LAYOUT TABLE 5.1 Sl. No. Cable Marker C-DOT Assy. No. From To Remarks On RSU Side * 1. RCX0 ACB-RSUXRCX0-000 2/1/

Strany 54 - 52 C-DOT DSS MAX-XL

Chapter 5. Sl. No. Cable Marker C-DOT Assy. No. From To Remarks 8. MB07 & MB08 ACB-MAXRMD08-000 CM/4/06/B/2 MDF 9. MA09 & MA10 ACB-MAXRM

Strany 55 - RSU INSTALLATION MANUAL 53

MDF - INSTALLATION Sl. No. Cable Marker C-DOT Assy. No. From To Remarks MA30 30. MA31 & MA32 ACB-MAXRMD30-000 CM/1/12/B/2 MDF RBM-16 31.

Strany 57

Chapter 5. Sl. No. Cable Marker C-DOT Assy. No. From To Remarks MA50 50. MA51 & MA52 ACB-MAXRMD50-000 CM/1/19/B/2 MDF RBM-26 51. MB49 &

Strany 58

RSU INSTALLATION MANUAL 5 Chapter 1. Introduction 1.1. GENERAL RSU, by definition, is the Remote Switching Unit of a geographically distributed exch

Strany 59

Chapter 1. 1. Only an even numbered BM can be made as an RSU 2. RSU Side : (BM-L/BM-XL) - To distinguish between a Remote Base Module and colocated

Strany 60

RSU INSTALLATION MANUAL 7 Chapter 2. Modifications in Floor Marking 2.1. MARKING OF SUITE LINES The suite lines are drawn as per the procedure outl