Chapter 2 – Fax Class1 Commands
Multi-Tech Systems, Inc. SocketModem MT5600SMI/MT5656SMI Reference Guide (S000306B) 73
Command: +FLO Flow Control
Description: This parameter allows the DTE to identify and select the type of flow control
used.
Syntax: +FLO=<method>
Defined Values: <method> Decimal number corresponding to the selected option.
0 XON/XOFF and RTS/CTS flow control turned off.
1 Use XON/XOFF flow control in either direction.
2 Use RTS for flow control of the modem by the DTE; use CTS for flow control
of the DTE by the modem.
Reporting Current or Selected Values:
Command: +FLO?
Response: +FLO: <method>
Example: +FLO: 0 For the default setting.
Reporting Supported Range of Parameter Values:
Command: +FLO=?
Response: +FLO: (<method>range)
Example: +FLO: (0-2)
Result Codes: OK <method> = 0-2.
ERROR Otherwise.