addresses are also unused. (For example, if you
use the base I/O address of 380h, addresses 380h-
387h must be unused.)
To select an unused I/O address and an IRQ value,
it may be necessary to find out which values are
already in use. To determine your system's current
settings, refer to Appendix A. ISI552PC port #1 is
shipped with the IRQ set to level 3 and the base I/O
address at 2F8 hex; and ISI552PC port #2 is shipped
with the IRQ set to level 4 and the base I/O address
at 3E8. If you are certain that these settings are not
already in use, continue with the hardware
configuration and installation.
Note: If you choose IRQ 3 or 4, you may have to
remove the serial I/O device from your
configuration files. The ISI552PC cards do not
allow you to select IRQ 6 because it is almost
universally used for the floppy drive of a
computer. Also, most computers will not be able
to assign IRQ 2 to the ISI because IRQ 2 is used
for slave control.