Chapter 7 – PING Services
Multi-Tech Systems, Inc. AT Commands for Wireless Modems with IP Connectivity (S000333D) 37
Chapter 7 – PING Services
Parameters Definitions
#PINGDELAY PING Delay Time
Definition: This command sets the waiting delay, in seconds, before an echo request is considered as a no reply.
It is also the delay between two echo requests (if PINGNUM > 1).
Values: From 1 to 255 inclusive. Default value is 1.
Syntax: Set Value: AT#PINGDELAY=<Value>
Get Value: AT#PINGDELAY? or AT#VPING, AT#VALL
#PINGNUM Number of PING Requests
Definition: This command sets the number of PING echo requests to issue to PINGREMOTE.
Values: From 1 to 255 inclusive. Default value is 4.
Syntax: Set Value: AT#PINGNUM=<Value>
Get Value: AT#PINGNUM? or AT#VPING, AT#VALL
#PINGREMOTE IP Address of PING Request
Definition: Sets the IP address or alphanumeric ASCII text string, up to 120 characters long if DNS is available.
Values: 32-bit number is dotted-decimal notation (i.e., xxx.xxx.xxx.xxx) or
Alphanumeric ASCII text string up to 120 characters if DNS is integrated. No default.
Syntax: Set Value: AT#PINGREMOTE=<Value>
Get Value: AT#PINGREMOTE? or AT#VPING, AT#VALL