Chapter 2 – Command Line Interface (CLI)
Command Line Interface and Application Examples for Multi-Tech Systems, Inc. IP Modules (S000368F) 26
Serial Commands – Set NMEA Filtering
Command Syntax set serial [s0] auto-dialin filter timer < 0 - 65535>
Description
Specifies the timer value in between successful sends in auto dial-in when filtering is
enabled.
This command is valid only for device port s0.
Default Value
0
Success
OK
Error 1. Too few arguments
“Usage: set serial s0 auto-dialin filter timer < 0 - 65535 >
Type ‘set serial s0 auto-dialin filter timer ?’ for more information”
2. Invalid argument
“Invalid argument”
Type ‘set serial s0 auto-dialin filter timer ?’ for more information”
3. If “set serial s1 auto-dialin filter timer 1” is given
“error: Invalid argument”. Arguments valid on s1 are displayed.
Command Syntax set serial [s0] auto-dialin filter add <1 - 10> <0 - 255> <string of 0 - 255 chars>
Description
Specifies 10 supported filters that can be applied on serial to network data, in auto
dial-in when filtering enabled.
This command is valid only for device port s0.
Default Value
NONE
Success
OK
Error 1. Too few arguments
“Usage: set serial s0 auto-dialin filter add <filter no: 1-10> <field no: 0-255>
<string of 0-255 chars>
Type ‘set serial s0 auto-dialin filter add ?’ for more information”
2. Invalid filter no
“Invalid line number <no>”
Invalid field no
"Possible value(s) are <1-10><0-255><string of length 0 -255>"
3. If “set serial s1 auto-dialin filter add <> <> <>” is given
“error: Invalid argument”. Arguments valid on s1 are displayed.
Command Syntax set serial [s0] auto-dialin filter delete < 1 - 10 >
Description
Deletes the specified filter from the filter table
This command is valid only for device port s0.
Default Value
NONE
Success
OK
Error 1. Too few arguments
"Too few arguments.
Usage: set serial s0 auto-dialin filter delete <filter no: 1 - 10>
Type ‘set serial s0 auto-dialin filter delete ?’ for more information”
2. Invalid filter no
“Invalid line number <no>”
3. If “set serial s1 auto-dialin filter delete <>” is given
“error: Invalid argument”. Arguments valid on s1 are displayed.